About this item
| Type | Value |
|---|---|
| Protection & Design | IP64 dust/drip proof (lid closed); protective fingerguards; ergonomic layout; robust for field use |
| Dimensions & Weight | Instrument + hard case: 330 × 410 × 180 mm; weight approx. 9 kg including battery and case |
| Storage Conditions | −20–60 °C; humidity ≤75% RH (no condensation) |
| Operating Conditions | Temperature: 0–40 °C (battery), –10–50 °C (AC); humidity ≤85% RH (no condensation); altitude ≤2000 m |
| Safety Standards | IEC 61010-1 CAT IV 600 V / CAT III 600 V; IEC 61010-2-030; IEC 61010-031; IEC 61326; IEC 60529 IP64 (lid closed); pollution degree 2; overload protection AC720 V/10 s; withstand voltages per sectio |
| Power Source | Rechargeable lead storage battery (12 V, 5 Ah) with built-in charger; AC power 100–240 V auto-switching; continuous operation approx. 4 hours under load at 12 kV; charge time ~8 h |
| Memory & Communication | Internal memory: up to ~43,000 data in 32 files; print-screen to BMP; USB adapter (MODEL 8212-USB) for PC transfer; PC software support |
| Filter Functions | Three modes (low-pass, moving average, combined) to stabilize readings |
| Auto-Discharge & Monitor | Yes; discharges capacitive charge after test; voltage monitor 30–6000 V resolution 10 V confirms discharge |
| Diagnostic Tests | PI, DAR, DD, SV with user-selectable intervals/time; automatic calculation and display of indices |
| Display | 5.7-inch (320×240) monochrome LCD with backlight; bar graph (36 points); overrange “OL” for resistance, “Hi” for voltage; low-battery indicator |
| Voltage Measurement | DC/AC 30–600 V; accuracy ±2% rdg ±3 dgt; frequency 45–65 Hz, ±0.2 Hz |
| Leakage & Capacitance | Leakage current display 5.0 nA to ~2.40 mA; capacitance measurement 5.0 nF–50 μF (500–5000 V), 40 nF–1 μF (10000/12000 V); accuracy ±5% rdg ±5 dgt |
| Short-Circuit Current | Max 5 mA across high-voltage ranges; rated output current ≥1 mA or more within specified load resistances |
| Output Voltage Accuracy | Monitor accuracy ±10% rdg ±20 V across ranges; output accuracy varies by range (e.g., 0–+20% at lower ranges, –5–+5% at highest) |
| Insulation Resistance | Max 500 GΩ at 500 V; 1.0 TΩ at 1000 V; 2.5 TΩ at 2500 V; 5.0 TΩ at 5000 V; 35.0 TΩ at 10000 V and 12000 V; accuracy ±5% rdg ±3 dgt for up to ~50–500 GΩ ranges, ±20% rdg beyond high-TΩ ranges; values displayed but not guaranteed above max. |