logo
Ar
Product Image

fluke 116C

Price 11,850.00 EG

In stock

About this item

fluke 116C

Total price 11,850.00 EG

Product Features

  • Digital multimeter designed specifically for HVAC professionals
  • Includes built-in thermometer to measure temperature from -40°C to z400°C (-40°F to 752°F)
  • Provides microamps to test flame sensors
  • Features low input impedance to helps prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated"" For HVAC technicians, building maintenance

Product Applications

  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

Specifications

TypeValue
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature -10°C to + 50°C
Storage temperature-40°C to + 60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
DC millivoltsRange/resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution 600.0 V / 0.1 V Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMSRange/resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
OhmsRange/resolution 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ Accuracy 0.9% + 1 Range/Resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% + 2
Diode TestRange/resolution 2.00 V / 0.001 V Accuracy 0.9% + 2
CapacitanceRange/resolution 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF Accuracy 1.9% + 2 Range/resolution > 1000 μF Accuracy 5% + 20%
Lo-Z CapacitanceRange 1 nF to 500 μF Accuracy 10% + 2 typical
Temperature² (Type-K thermocouple)Range/resolution -40°C to 400°C / 0.1°C Accuracy 1% + 10² Range/resolution -40°F to 752°F / 0.2°F Accuracy 1% + 18²
AC μA true-rms (45 Hz to 500 Hz)Range/resolution 600.0 μA / 0.1 μA Accuracy 1.5% + 3
MTM